Manufacture and Supplier of Electronic Passive Components, Backplanes, Power Supply, Display Monitors, Display, Electronic Components, Passive Components Available at Wholesale Prices
Backplanes
 
Backplanes VME or CPCI
 
VME 64X Backplane
 

The VME64x is an extension of the VME family according to ANSI/VITA 1.1-1997 and permits 64-bit data traffic. This system is downward compatible, so that assemblies with 96-pin connectors to DIN 41612 can be inserted in the 160-pin socket connectors on the backplane.

 
 
Following options are available:
   

Manual Daisy Chaining
In the case of unused slots, the daisy chain signals can be bridged by means of jumpers or wire-wrap connections from the front or rear of the backplane.
Power is supplied via screw connections and terminal bars.

   

Automatic Daisy Chaining
Automatic daisy chain wiring with OR gates makes manual setting of jumpers unnecessary.

   

Live Insertion and Automatic Daisy Chain
Live Insertion does not require additional modules; these have already been integrated in the backplane. Automatic daisy chain wiring with OR gates makes manual setting of jumpers unnecessary.

 
CPCI Backplanes:
 

General and technical Information
The CompactPCI bus is compatible with the PCI bus known from the PC world as far as the electrical specifications are concerned. The mechanical specifications were adapted to the commonly used Euro-board plug-in system in the 19? card rack. Therefore this bus is also suitable for industrial purposes. Previously unattained signal speeds supported by the layout technology developed by Guarantee more stability and reliability for assemblies operating in the limit range. The backplanes are distinguished by a completely novel energy buffering feature which works across the entire frequency range. This feature guarantees improved reliability thanks to more stable supply voltages directly at the slot in conjunction with fluctuating loads.

Chassis GND connection
A continuous electrically conductive chassis GND surface is located in the area where the bus board is mounted on the card rack. An M3 screw connection is available to connect the chassis ground. By installing a connecting bracket or terminal bar, the chassis GND can be connected to GND in a low-resistance star arrangement.

JTAG connector
A separate 6-pin connector for JTAG boundary scan is implemented on the backplane.
Faster, simpler system initialization and testing by means of the JTAG bus even in the completely mounted state are achieved by direct access via an additional connector on the backplane.

Utility connector
The special signals to the power supply unit and external LEDs are routed to separate plug-in connectors on the backplanes. Depending on the backplane type, either a 10-pin or a 14-pin connector is used.

ATX connector
The ATX power supply connector used in the PC world is integrated in some backplane variants.
This results in a highly efficient and economic solution for supplying power to the backplane via ATX connectors and for the wiring of fans and drives.

 
Power Supply
 
CompactPCI Power Supply:
 

CompactPCI AC/DC power supplies deliver up to 500W continuous power. Products are compliant with the PICMG® 2.11 power interface specification using the standard Positronic 47-pin connector.

Two converters in parallel, one for the +3.3V and the other for the +5V, enable the user the flexibility to determine unique load requirements for each channel independently. Full load can be drawn from each channel independently.

 
Input Requirement:
 

Dc Inpute Dc INput Voltage

36 - 72 VDC

Input Inrush Current

20AMax.

Input Reflected Ripple

FCC-68 part 15 & EN55022 Class B with the use of an external line filter

Active Power Factor Correction

 

Efficiency @ 48/24VDC

83% @ 48VDC

Input Line Protection

Non-User Serviceable Fuse

V1/Current

+5VDC /50A

V2/Current

+3.3VDC / 80A

V3/Current

+12VDC / 7.5A

V4/Current

-12VDC / 1.5A

Aux V/Current

N/A

Total Output Power    

400W with 250LFM ( 500W With 400LFM - Safety Pending

Line Regulation 

+/- 0.5%

Hot-Swap         

Yes

Current Share   

Single Wire - on V1 & V2

Remote Sense (Open sense lines protected)

On +5VDC & +3.3VDC

Long Term Stability

0.1% over 10 Hours after 10min. Warm Up

   

Enviromental:

 

   

Operation

-5C to +55C with 250LFM Forced Air Cooling

Storage

-40C to +85C

Cooling

250LFM Forced Air Cooling

Humidity

Up to 95% RH Non-Condensing

Shock and Vibration Storage

: EN 300 019-2-1 Storage class 1.2′ EN 300 019-2-2

Transportation

class 2.3′ EN 300 019-2-3 Use class 3.3

 
Display Monitors
 

Dinrack is authorized distributor of KME displays for Indian Region. Click on the link below to explore the vide range of Displays manufactured by KME
www.kme.co.uk

 
Backplanes
 
 
Power Supply
 
 
 
Display
 
Industrial 19" Racks
19" Racks, Enclosure, Cabinets
   
Networking, Data and Telecom Cabinets
Softline Racks
Cabinet with a Swing Frame
  Wall Mounted, Outdoor Enclosures
  Subrack - EURO, VME, CPCI
   
Industrial card racks
  19 inch chassis, Table Top cases
   
19 inch Rack mountable DR 30 and DR 31